{"id":56535,"date":"2026-06-24T10:42:06","date_gmt":"2026-06-24T08:42:06","guid":{"rendered":"https:\/\/arbrea-labs.com\/?p=56535"},"modified":"2026-06-24T11:40:02","modified_gmt":"2026-06-24T09:40:02","slug":"novo-estudo-clinico-usa-o-arbrea-breast-3d-para-revelar-como-o-tipo-de-implante-molda-os-resultados-de-longo-prazo-do-aumento-de-mama","status":"publish","type":"post","link":"https:\/\/arbrea-labs.com\/pt\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/","title":{"rendered":"Novo Estudo Cl\u00ednico Utiliza Arbrea Breast 3D para Revelar Como o Tipo de Implante Molda Resultados de Longo Prazo da Mamoplastia de Aumento"},"content":{"rendered":"<div id=\"fws_6a3da3701188e\"  data-column-margin=\"default\" data-midnight=\"dark\"  class=\"wpb_row vc_row-fluid vc_row\"  style=\"padding-top: 0px; padding-bottom: 0px; \"><div class=\"row-bg-wrap\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"false\"><div class=\"inner-wrap row-bg-layer\" ><div class=\"row-bg viewport-desktop\"  style=\"\"><\/div><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding inherit_tablet inherit_phone flex_gap_desktop_10px\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<p data-sourcepos=\"7:1-7:26;384-409\">Um novo estudo cl\u00ednico usa <a href=\"https:\/\/arbrea-labs.com\/pt\/mama\/\">Arbrea Breast 3D<\/a> para rastrear objetivamente como cinco tipos diferentes de implantes mam\u00e1rios se comportam ao longo de 12 meses. Publicada no Aesthetic Surgery Journal, esta pesquisa prospectiva revisada por pares \u00e9 a compara\u00e7\u00e3o baseada em medi\u00e7\u00f5es mais detalhada de estabilidade de implantes at\u00e9 o momento.<\/p>\n<h3 class=\"text-text-100 mt-3 -mb-1 text-&#091;1.125rem&#093; font-bold\" data-sourcepos=\"7:1-7:26;384-409\"><strong>Por que este estudo \u00e9 importante<\/strong><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal\">Cirurgi\u00f5es que escolhem um implante mam\u00e1rio consideram muitos fatores, incluindo formato, volume, firmeza do gel e textura da superf\u00edcie. No entanto, dados objetivos de longo prazo sobre como essas escolhas se manifestam em pacientes reais t\u00eam sido limitados. Grande parte das evid\u00eancias dispon\u00edveis depende de avalia\u00e7\u00f5es subjetivas ou per\u00edodos de acompanhamento curtos, deixando os cirurgi\u00f5es sem uma imagem confi\u00e1vel de como os implantes se comportam ao longo do tempo.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal\">O Dr. Giovanni Bistoni, o Dr. Pietro Luciano Serra e a Dra. Melba Lattanzi se propuseram a mudar isso. Seu estudo prospectivo, publicado no Aesthetic Surgery Journal (Volume 46, Edi\u00e7\u00e3o 7, 2026), colocou a Arbrea no centro da metodologia.<\/p>\n<hr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\" \/>\n<h3 class=\"text-text-100 mt-3 -mb-1 text-&#091;1.125rem&#093; font-bold\" data-sourcepos=\"15:1-15:77;1054-1130\"><strong>Vis\u00e3o Geral do Estudo: 106 Pacientes, 5 Tipos de Implantes, 12 Meses de Monitoramento 3D<\/strong><\/h3>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">T<\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"1\">A equipe de pesquisa inscreveu 106 pacientes <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"40\">(212 mamas) sendo submetidas a procedimento prim\u00e1rio <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"73\">mamoplastia de aumento em um <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"98\">cl\u00ednica particular individual. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"123\">O recrutamento ocorreu ao longo de dois <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"155\">anos, de junho de 2022 a junho de <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"185\">2024. Cada paciente foi ent\u00e3o <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"213\">seguido individualmente por 12 <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"242\">meses p\u00f3s-operat\u00f3rios. Todos <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"270\">procedimentos foram realizados por <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"303\">mesmo cirurgi\u00e3o usando um <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"324\">t\u00e9cnica de plano duplo por baixo da mama<\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"357\">\u00a0incis\u00e3o em dobra. Este <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"390\">escolha de design deliberada minimizada <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"425\">variabilidade e implante isolado <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"458\">caracter\u00edsticas como o principal <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"489\">vari\u00e1vel.<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">Cinco tipos de implantes foram <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"24\">inclu\u00eddo no estudo:<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<ul class=\"&#091;li_&amp;&#093;:mb-0 &#091;li_&amp;&#093;:mt-1 &#091;li_&amp;&#093;:gap-1 &#091;&amp;:not(:last-child)_ul&#093;:pb-1 &#091;&amp;:not(:last-child)_ol&#093;:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\">Gel Progressivo ULTIMA (PgU), liso e redondo<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\">Gel HSC+, liso e redondo<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\">Redondo, microtexturizado (gel HSC+)<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\">Anat\u00f4mico, microtexturizado (HSC+ gel)<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\">Anat\u00f4mico, revestido de poliuretano (PU)<\/li>\n<\/ul>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">Cirurgi\u00f5es avaliaram <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"18\">pacientes no pr\u00e9-operat\u00f3rio, aos 6 <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"48\">meses, e novamente aos 12 meses. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"80\">A cada visita, a equipe <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"104\">usado o software Arbrea para <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"128\">medi\u00e7\u00e3o baseada em 3D <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"152\">An\u00e1lise de 2D padronizado <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"182\">fotografias. Dois indicadores-chave <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"214\">comportamento do implante foram <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"239\">medido em cada acompanhamento:<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<ul class=\"&#091;li_&amp;&#093;:mb-0 &#091;li_&amp;&#093;:mt-1 &#091;li_&amp;&#093;:gap-1 &#091;&amp;:not(:last-child)_ul&#093;:pb-1 &#091;&amp;:not(:last-child)_ol&#093;:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"4\">Dist\u00e2ncia do mamilo \u00e0 dobra inframam\u00e1ria (N-IMF):<\/span><\/strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"4\"> uma medida direta de <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"72\">alongamento do polo inferior, gravado <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"104\">em cent\u00edmetros<\/span><\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"123\">Propor\u00e7\u00e3o de p\u00f3los baixos (LPR)<\/span><\/strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"123\"> o <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"153\">porcentagem do volume do polo inferior <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"185\">em rela\u00e7\u00e3o ao volume total da mama<\/span><\/li>\n<\/ul>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<hr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\" \/>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<h3 class=\"font-claude-response-body break-words whitespace-normal\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\">Por Que Essas Medidas Importam<\/span><\/strong><\/h3>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">Inferior<\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"5\"> o alongamento de pole \u00e9 um dos mais <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"41\">altera\u00e7\u00f5es clinicamente significativas <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"72\">que pode ocorrer ap\u00f3s cirurgia mam\u00e1ria <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"100\">aumento. Pouco alongamento <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"136\">no come\u00e7o <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"149\">p\u00f3s-operat\u00f3rio pode indicar um <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"185\">Resultado apertado e antinatural. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"213\">Por outro lado, esticar demais<\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"241\">, particularmente em pacientes <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"278\">com frouxid\u00e3o dos tecidos, pode levar a <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"310\">atingir o fundo, implante <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"333\">deslocamento e cirurgia de revis\u00e3o. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"369\">Rastreamento de N-IMF e LPR ao longo do tempo <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"402\">portanto, oferece aos cirurgi\u00f5es um <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"430\">vis\u00e3o objetiva de como o <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"456\">implante est\u00e1 interagindo com <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"484\">tecido circundante. Antes das ferramentas <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"517\">como Arbrea, cirurgi\u00f5es tiveram que <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"546\">confie apenas na avalia\u00e7\u00e3o visual.<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<hr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\" \/>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<h3 class=\"font-claude-response-body break-words whitespace-normal\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\">Principais Conclus\u00f5es: Nem Todos os Implantes Se Comportam da Mesma Forma<\/span><\/strong><\/h3>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">O estudo descobriu um <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"18\">classifica\u00e7\u00e3o clara da estabilidade do implante <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"53\">em todos os cinco grupos. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"77\">No geral, textura da superf\u00edcie e firmeza do gel<\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"110\">\u00a0os dois fatores que <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"147\">fez a maior diferen\u00e7a.<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\">Implantes de silicone: A maior mudan\u00e7a ao longo do tempo<\/span><\/strong><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">Primeiro, rodada PgU suave <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"24\">implantes mudaram mais. Entre 6 <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"61\">e 12 meses, a <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"80\">dist\u00e2ncia do mamilo at\u00e9 o sulco submam\u00e1rio <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"117\">aumentou em quase 1 cm em m\u00e9dia, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"154\">e a participa\u00e7\u00e3o do volume do polo inferior aumentou em <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"194\">quase 7 pontos percentuais. Isso <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"227\">acontece porque o gel PgU mais macio <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"262\">desloca para baixo quando o paciente est\u00e1 <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"298\">ereto, gradualmente esticando o inferior <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"338\">polo ao longo do tempo. Como resultado, o <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"371\">o resultado pode parecer natural e cheio. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"406\">No entanto, isso tamb\u00e9m significa que esses implantes <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"444\">carregar mais risco em pacientes com macio <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"482\">ou tecido solto. Da mesma forma, HSC+ liso <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"522\">implantes redondos mostraram distens\u00e3o moderada<\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"553\">, aproximadamente metade da de PgU <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"590\">implantes, com melhor polo superior <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"623\">plenitude preservada. No entanto, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"657\">uma mudan\u00e7a mensur\u00e1vel ainda ocorreu <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"690\">entre 6 e 12 meses.<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\">Implantes Texturizados: Melhor Controle, Mais Previsibilidade<\/span><\/strong><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">Em contraste, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"13\">microtextured implants, both round and <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"52\">anatomical, sat comfortably in the <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"87\">middle. Adding surface texture and <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"122\">increasing gel firmness slowed down <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"160\">tissue adaptation without stopping it <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"198\">entirely. Therefore, these implants <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"234\">offer a strong middle ground for <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"267\">patients who need positional control <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"304\">but still want a natural feel.<\/span><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><strong><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"2\">Polyurethane-Coated Implants: Virtually No Movement<\/span><\/strong><\/p>\n<\/div>\n<div class=\"_chunkWrapper_6ta1u_30\">\n<p class=\"font-claude-response-body break-words whitespace-normal\"><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"0\">Most remarkably, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"17\">polyurethane-coated anatomical implants <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"57\">barely moved at all. Over the full <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"92\">12-month period, the average change in <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"131\">lower pole distance was just 0.04 cm, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"169\">which is statistically zero. This is <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"206\">because the polyurethane coating <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"239\">encourages surrounding tissue to grow <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"277\">into the implant surface early on, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"312\">effectively locking it in place. <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"345\">Consequently, PU-coated implants proved <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"385\">to be the most stable option, <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"415\">particularly for active patients or <\/span><span class=\"_animating_6ta1u_10\" data-newtext-seq=\"451\">those with tissue looseness.<\/span><\/p>\n<hr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\" \/>\n<\/div>\n<h3 class=\"font-claude-response-body break-words whitespace-normal\"><strong>Complications: Less Stability Means Higher Risk<\/strong><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal\">The overall complication rate across the entire cohort was 2.4% per implant. Importantly, all complications occurred in the smooth round groups. Furthermore, smooth PgU round implants showed a statistically significant association with repeat surgery (p = .011). Complications included one case of medial implant displacement linked to rib cage asymmetry, and three cases of inferior displacement associated with large implant volumes and failure to follow postoperative activity restrictions. Notably, no capsular contractures, infections, hematomas, or ruptures were recorded across any group. In contrast, the PU-coated, microtextured round, and microtextured anatomical groups recorded zero complications, supporting the idea that surface fixation mechanisms reduce early dislocation risk.<\/p>\n<hr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\" \/>\n<h3 class=\"font-claude-response-body break-words whitespace-normal\"><strong>Patient Satisfaction: High Across All Groups<\/strong><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal\">The team assessed patient satisfaction at 12 months using a Likert scale from 1 to 5. All groups returned high scores, and no statistically significant difference between implant types was found (p &gt; .05). In other words, patients reported satisfaction regardless of which implant they received. Interestingly, anatomical implants showed a positive trend and were the most appreciated shape in the cohort overall.<\/p>\n<\/div>\n\n\n\n\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t<div id=\"fws_6a3da37012248\"  data-column-margin=\"default\" data-midnight=\"dark\"  class=\"wpb_row vc_row-fluid vc_row\"  style=\"padding-top: 0px; padding-bottom: 0px; \"><div class=\"row-bg-wrap\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"false\"><div class=\"inner-wrap row-bg-layer\" ><div class=\"row-bg viewport-desktop\"  style=\"\"><\/div><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding inherit_tablet inherit_phone flex_gap_desktop_10px\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1782293997256\" >\n\t<div class=\"\">\n<h3><strong>A Practical Decision-Making Framework for Surgeons<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Based on their findings, the authors proposed a clinical algorithm that matches implant selection to individual anatomical characteristics and aesthetic goals.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Implant<\/th>\n<th>Best Suited For<\/th>\n<th>Less Appropriate For<\/th>\n<\/tr>\n<tr>\n<td>Smooth PgU Round<\/td>\n<td>Younger, physically active individuals, firm soft-tissue support, constricted lower pole, preference for a natural sensation<\/td>\n<td>Lax soft-tissue support, thoracic asymmetries<\/td>\n<\/tr>\n<tr>\n<td>Smooth HSC+ Round<\/td>\n<td>Greater upper-pole fullness, strong tissue support, natural tactile qualities<\/td>\n<td>Lax support structures, chest wall asymmetries<\/td>\n<\/tr>\n<tr>\n<td>Microtextured Round<\/td>\n<td>Active lifestyles, enhanced upper-pole projection, medium-to-large implant volumes<\/td>\n<td>Cases where a softer feel is preferred or support is limited<\/td>\n<\/tr>\n<tr>\n<td>Microtextured Anatomical<\/td>\n<td>Gradual upper-pole transition, mild laxity, thoracic asymmetry<\/td>\n<td>Very active individuals seeking pronounced upper-pole fullness<\/td>\n<\/tr>\n<tr>\n<td>PU-Coated Anatomical<\/td>\n<td>High activity levels, reduced tissue support, chest wall irregularities<\/td>\n<td>Preference for maximum softness<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>O que isso significa para a cirurgia est\u00e9tica<\/strong><\/h3>\n<p class=\"isSelectedEnd\">This study adds rigorous, prospective, 3D-validated evidence to a field that has often relied on short-term outcomes and subjective clinical judgment. Implant design emerges as a key determinant of long-term shape stability. Gel cohesivity and surface characteristics are more than technical features; they produce measurable effects on breast form and behavior 12 months after augmentation. Implant volume also plays an independent role. Larger devices demonstrated greater elongation across all categories, underscoring the value of limiting mechanical stress on supporting structures.<\/p>\n<p>Finally, 3D morphometric assessment enables truly evidence-based follow-up. Objective measurement systems help clinicians identify changes sooner, provide more accurate guidance, and support revision planning with quantifiable data rather than subjective observation.<\/p>\n<\/div>\n<\/div>\n\n\n\n\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t<div id=\"fws_6a3da37012560\"  data-column-margin=\"default\" data-midnight=\"dark\"  class=\"wpb_row vc_row-fluid vc_row\"  style=\"padding-top: 0px; padding-bottom: 0px; \"><div class=\"row-bg-wrap\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"false\"><div class=\"inner-wrap row-bg-layer\" ><div class=\"row-bg viewport-desktop\"  style=\"\"><\/div><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding inherit_tablet inherit_phone flex_gap_desktop_10px\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<h2><strong>Autores<\/strong><\/h2>\n<\/div>\n\n\n\n<div id=\"fws_6a3da37012899\" data-midnight=\"\" data-column-margin=\"custom\" class=\"wpb_row vc_row-fluid vc_row inner_row vc_row-o-equal-height vc_row-flex vc_row-o-content-middle column-margin-7pct top_padding_tablet_7pct top_padding_phone_0px bottom_padding_tablet_7pct bottom_padding_phone_0px\"  style=\"padding-top: 2%; padding-bottom: 2%; \"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column left_padding_phone_10pct right_padding_phone_10pct flex_gap_desktop_10px\"    data-t-w-inherits=\"small_desktop\" data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap center custom-size mask_shape_circle mask_size_contain\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <a href=\"https:\/\/www.instagram.com\/reel\/C9fXFZaqc58\/?utm_source=ig_web_copy_link&#038;igsh=MzRlODBiNWFlZA==\" target=\"_self\" class=\"center\">\n              <img decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"150\" width=\"150\" data-animation=\"none\" src=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/image_2026-06-24_170603112-150x150.png\" alt=\"\" srcset=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/image_2026-06-24_170603112-150x150.png 150w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/image_2026-06-24_170603112-12x12.png 12w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/image_2026-06-24_170603112-140x140.png 140w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/image_2026-06-24_170603112-100x100.png 100w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/image_2026-06-24_170603112-300x300.png 300w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/>\n            <\/a>\n          <\/div>\n        <\/div>\n        \n      <\/div>\n      <\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-8 wpb_column column_container vc_column_container col child_column no-extra-padding inherit_tablet inherit_phone flex_gap_desktop_10px\"    data-t-w-inherits=\"small_desktop\" data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"nectar-responsive-text font_size_max_32px font_size_tablet_2vw font_size_phone_4vw font_line_height_1-5 nectar-link-underline-effect\"><h5><strong>Dr. Giovanni Bistoni, MD<\/strong><\/h5>\n<\/div><div class=\"nectar-responsive-text nectar-link-underline-effect\"><p><strong>Dr. Giovanni Bistoni, MD<\/strong> \u2014 Plastic surgeon, key opinion leader for Silimed. Corresponding study lead.<\/p>\n<\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6a3da370130c8\" data-midnight=\"\" data-column-margin=\"custom\" class=\"wpb_row vc_row-fluid vc_row inner_row vc_row-o-equal-height vc_row-flex vc_row-o-content-middle column-margin-7pct top_padding_tablet_7pct top_padding_phone_0px bottom_padding_tablet_7pct bottom_padding_phone_0px\"  style=\"padding-top: 2%; padding-bottom: 2%; \"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column left_padding_phone_10pct right_padding_phone_10pct flex_gap_desktop_10px\"    data-t-w-inherits=\"small_desktop\" data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap center custom-size mask_shape_circle mask_size_contain\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <a href=\"https:\/\/www.instagram.com\/reel\/C9fXFZaqc58\/?utm_source=ig_web_copy_link&#038;igsh=MzRlODBiNWFlZA==\" target=\"_self\" class=\"center\">\n              <img decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"150\" width=\"150\" data-animation=\"none\" src=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-150x150.jpg\" alt=\"\" srcset=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-150x150.jpg 150w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-140x140.jpg 140w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-100x100.jpg 100w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-500x500.jpg 500w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-350x350.jpg 350w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-1000x1000.jpg 1000w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-800x800.jpg 800w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/4d7a10a6-11bf-4bf6-ae69-d046aef1b78d_large-300x300.jpg 300w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/>\n            <\/a>\n          <\/div>\n        <\/div>\n        \n      <\/div>\n      <\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-8 wpb_column column_container vc_column_container col child_column no-extra-padding inherit_tablet inherit_phone flex_gap_desktop_10px\"    data-t-w-inherits=\"small_desktop\" data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"nectar-responsive-text font_size_max_32px font_size_tablet_2vw font_size_phone_4vw nectar-link-underline-effect\"><h5><strong>Dr. Pietro Luciano Serra, MD<\/strong><\/h5>\n<\/div><div class=\"nectar-responsive-text nectar-link-underline-effect\"><p data-start=\"777\" data-end=\"1015\"><strong>Dr. Pietro Luciano Serra, MD<\/strong> \u2014 Division of Plastic Surgery, University of Modena and Reggio Emilia.<\/p>\n<\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6a3da37013718\" data-midnight=\"\" data-column-margin=\"custom\" class=\"wpb_row vc_row-fluid vc_row inner_row vc_row-o-equal-height vc_row-flex vc_row-o-content-middle column-margin-7pct top_padding_tablet_7pct top_padding_phone_0px bottom_padding_tablet_7pct bottom_padding_phone_0px\"  style=\"padding-top: 2%; padding-bottom: 2%; \"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column left_padding_phone_10pct right_padding_phone_10pct flex_gap_desktop_10px\"    data-t-w-inherits=\"small_desktop\" data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap center custom-size mask_shape_circle mask_size_contain\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <a href=\"https:\/\/www.instagram.com\/reel\/C9fXFZaqc58\/?utm_source=ig_web_copy_link&#038;igsh=MzRlODBiNWFlZA==\" target=\"_self\" class=\"center\">\n              <img decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"150\" width=\"150\" data-animation=\"none\" src=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/1773320126856-150x150.jpg\" alt=\"Melba Lattanzi, MD\" srcset=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/1773320126856-150x150.jpg 150w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/1773320126856-12x12.jpg 12w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/1773320126856-140x140.jpg 140w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/1773320126856-100x100.jpg 100w, https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/06\/1773320126856.jpg 200w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/>\n            <\/a>\n          <\/div>\n        <\/div>\n        \n      <\/div>\n      <\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-8 wpb_column column_container vc_column_container col child_column no-extra-padding inherit_tablet inherit_phone flex_gap_desktop_10px\"    data-t-w-inherits=\"small_desktop\" data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"nectar-responsive-text font_size_tablet_2vw font_size_phone_4vw nectar-link-underline-effect\"><h5>Dr. Melba Lattanzi, MD<\/h5>\n<\/div><div class=\"nectar-responsive-text nectar-link-underline-effect\"><p data-start=\"497\" data-end=\"733\"><strong>Dr. Melba Lattanzi, MD<\/strong> \u2014 Division of Plastic Surgery, Policlinico of Modena, University of Modena and Reggio Emilia.<\/p>\n<\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>","protected":false},"excerpt":{"rendered":"Um novo estudo cl\u00ednico utiliza o Arbrea Breast 3D para rastrear objetivamente o comportamento de cinco tipos diferentes de implantes mam\u00e1rios ao longo de 12 meses. Publicado na Aesthetic...","protected":false},"author":125,"featured_media":55384,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1,694],"tags":[],"class_list":["post-56535","post","type-post","status-publish","format-standard","has-post-thumbnail","category-arbrea-blog","category-publications"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.7 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>New Clinical Studies Uses Arbrea Breast 3D Technology<\/title>\n<meta name=\"description\" content=\"Discover how clinical studies use Arbrea Breast 3D for a detailed analysis of different breast implant types and their long-term behavior.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/arbrea-labs.com\/pt\/novo-estudo-clinico-usa-o-arbrea-breast-3d-para-revelar-como-o-tipo-de-implante-molda-os-resultados-de-longo-prazo-do-aumento-de-mama\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"New Clinical Study Uses Arbrea Breast 3D to Reveal How Implant Type Shapes Long-Term Breast Augmentation Outcomes\" \/>\n<meta property=\"og:description\" content=\"Discover how clinical studies use Arbrea Breast 3D for a detailed analysis of different breast implant types and their long-term behavior.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/arbrea-labs.com\/pt\/novo-estudo-clinico-usa-o-arbrea-breast-3d-para-revelar-como-o-tipo-de-implante-molda-os-resultados-de-longo-prazo-do-aumento-de-mama\/\" \/>\n<meta property=\"og:site_name\" content=\"Arbrea Labs\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/arbrealabs\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-24T08:42:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-24T09:40:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/03\/Untitled-design-3-1-1-1024x683.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"erakernaja\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"erakernaja\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/\"},\"author\":{\"name\":\"erakernaja\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#\\\/schema\\\/person\\\/069e36014f41639cb4e9fb98fbdc8b21\"},\"headline\":\"New Clinical Study Uses Arbrea Breast 3D to Reveal How Implant Type Shapes Long-Term Breast Augmentation Outcomes\",\"datePublished\":\"2026-06-24T08:42:06+00:00\",\"dateModified\":\"2026-06-24T09:40:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/\"},\"wordCount\":2868,\"publisher\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/arbrea-labs.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Untitled-design-3-1-1.png\",\"articleSection\":[\"Arbrea Blog\",\"Publications\"],\"inLanguage\":\"pt-BR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/\",\"url\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/\",\"name\":\"New Clinical Studies Uses Arbrea Breast 3D Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/arbrea-labs.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Untitled-design-3-1-1.png\",\"datePublished\":\"2026-06-24T08:42:06+00:00\",\"dateModified\":\"2026-06-24T09:40:02+00:00\",\"description\":\"Discover how clinical studies use Arbrea Breast 3D for a detailed analysis of different breast implant types and their long-term behavior.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/arbrea-labs.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Untitled-design-3-1-1.png\",\"contentUrl\":\"https:\\\/\\\/arbrea-labs.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Untitled-design-3-1-1.png\",\"width\":2560,\"height\":1707,\"caption\":\"natural breast implants\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/arbrea-labs.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"New Clinical Study Uses Arbrea Breast 3D to Reveal How Implant Type Shapes Long-Term Breast Augmentation Outcomes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#website\",\"url\":\"https:\\\/\\\/arbrea-labs.com\\\/\",\"name\":\"Arbrea Labs\",\"description\":\"Augmented Reality &amp; 3D Solutions for Aesthetics\",\"publisher\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#organization\"},\"alternateName\":\"Arbrea\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/arbrea-labs.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#organization\",\"name\":\"Arbrea Labs\",\"alternateName\":\"Arbrea\",\"url\":\"https:\\\/\\\/arbrea-labs.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/arbrea-labs.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logo_arbrea_LABS-01-1-e1641392734450.png\",\"contentUrl\":\"https:\\\/\\\/arbrea-labs.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logo_arbrea_LABS-01-1-e1641392734450.png\",\"width\":2000,\"height\":750,\"caption\":\"Arbrea Labs\"},\"image\":{\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/arbrealabs\",\"https:\\\/\\\/www.instagram.com\\\/arbrealabs\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/arbrea-labs-ag\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCbHN9gofXJv8rMAHcAguTcg\"],\"description\":\"Arbrea Labs leads the way in blending advanced AI technology with personalized healthcare. Our fast, simple and safe Augmented Reality & 3D simulators optimize consultations, saving time and enhancing patient education. Meanwhile, our AR-driven marketing booster enhances patient journeys, maximizing marketing ROI and fostering efficient lead generation. Join us as we shape the future of aesthetic healthcare.\",\"email\":\"info@arbrea-labs.com\",\"legalName\":\"Arbrea Labs AG\",\"foundingDate\":\"2018-03-04\",\"vatID\":\"CHE-292.633.177\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"11\",\"maxValue\":\"50\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/arbrea-labs.com\\\/#\\\/schema\\\/person\\\/069e36014f41639cb4e9fb98fbdc8b21\",\"name\":\"erakernaja\",\"url\":\"https:\\\/\\\/arbrea-labs.com\\\/pt\\\/author\\\/ad39b824856cb51b\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Novos Estudos Cl\u00ednicos Utilizam a Tecnologia Arbrea Breast 3D","description":"Descubra como estudos cl\u00ednicos utilizam o Arbrea Breast 3D para uma an\u00e1lise detalhada de diferentes tipos de implantes mam\u00e1rios e seu comportamento a longo prazo.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/arbrea-labs.com\/pt\/novo-estudo-clinico-usa-o-arbrea-breast-3d-para-revelar-como-o-tipo-de-implante-molda-os-resultados-de-longo-prazo-do-aumento-de-mama\/","og_locale":"pt_BR","og_type":"article","og_title":"New Clinical Study Uses Arbrea Breast 3D to Reveal How Implant Type Shapes Long-Term Breast Augmentation Outcomes","og_description":"Discover how clinical studies use Arbrea Breast 3D for a detailed analysis of different breast implant types and their long-term behavior.","og_url":"https:\/\/arbrea-labs.com\/pt\/novo-estudo-clinico-usa-o-arbrea-breast-3d-para-revelar-como-o-tipo-de-implante-molda-os-resultados-de-longo-prazo-do-aumento-de-mama\/","og_site_name":"Arbrea Labs","article_publisher":"https:\/\/www.facebook.com\/arbrealabs","article_published_time":"2026-06-24T08:42:06+00:00","article_modified_time":"2026-06-24T09:40:02+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/03\/Untitled-design-3-1-1-1024x683.png","type":"image\/png"}],"author":"erakernaja","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"erakernaja","Est. tempo de leitura":"7 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#article","isPartOf":{"@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/"},"author":{"name":"erakernaja","@id":"https:\/\/arbrea-labs.com\/#\/schema\/person\/069e36014f41639cb4e9fb98fbdc8b21"},"headline":"New Clinical Study Uses Arbrea Breast 3D to Reveal How Implant Type Shapes Long-Term Breast Augmentation Outcomes","datePublished":"2026-06-24T08:42:06+00:00","dateModified":"2026-06-24T09:40:02+00:00","mainEntityOfPage":{"@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/"},"wordCount":2868,"publisher":{"@id":"https:\/\/arbrea-labs.com\/#organization"},"image":{"@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#primaryimage"},"thumbnailUrl":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/03\/Untitled-design-3-1-1.png","articleSection":["Arbrea Blog","Publications"],"inLanguage":"pt-BR"},{"@type":"WebPage","@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/","url":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/","name":"Novos Estudos Cl\u00ednicos Utilizam a Tecnologia Arbrea Breast 3D","isPartOf":{"@id":"https:\/\/arbrea-labs.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#primaryimage"},"image":{"@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#primaryimage"},"thumbnailUrl":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/03\/Untitled-design-3-1-1.png","datePublished":"2026-06-24T08:42:06+00:00","dateModified":"2026-06-24T09:40:02+00:00","description":"Descubra como estudos cl\u00ednicos utilizam o Arbrea Breast 3D para uma an\u00e1lise detalhada de diferentes tipos de implantes mam\u00e1rios e seu comportamento a longo prazo.","breadcrumb":{"@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#primaryimage","url":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/03\/Untitled-design-3-1-1.png","contentUrl":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2026\/03\/Untitled-design-3-1-1.png","width":2560,"height":1707,"caption":"natural breast implants"},{"@type":"BreadcrumbList","@id":"https:\/\/arbrea-labs.com\/new-clinical-study-uses-arbrea-breast-3d-to-reveal-how-implant-type-shapes-long-term-breast-augmentation-outcomes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/arbrea-labs.com\/"},{"@type":"ListItem","position":2,"name":"New Clinical Study Uses Arbrea Breast 3D to Reveal How Implant Type Shapes Long-Term Breast Augmentation Outcomes"}]},{"@type":"WebSite","@id":"https:\/\/arbrea-labs.com\/#website","url":"https:\/\/arbrea-labs.com\/","name":"Laborat\u00f3rios Arbrea","description":"Solu\u00e7\u00f5es de Realidade Aumentada e 3D para Est\u00e9tica","publisher":{"@id":"https:\/\/arbrea-labs.com\/#organization"},"alternateName":"Arbrea","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/arbrea-labs.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/arbrea-labs.com\/#organization","name":"Laborat\u00f3rios Arbrea","alternateName":"Arbrea","url":"https:\/\/arbrea-labs.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/arbrea-labs.com\/#\/schema\/logo\/image\/","url":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2022\/01\/logo_arbrea_LABS-01-1-e1641392734450.png","contentUrl":"https:\/\/arbrea-labs.com\/wp-content\/uploads\/2022\/01\/logo_arbrea_LABS-01-1-e1641392734450.png","width":2000,"height":750,"caption":"Arbrea Labs"},"image":{"@id":"https:\/\/arbrea-labs.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/arbrealabs","https:\/\/www.instagram.com\/arbrealabs\/","https:\/\/www.linkedin.com\/company\/arbrea-labs-ag\/","https:\/\/www.youtube.com\/channel\/UCbHN9gofXJv8rMAHcAguTcg"],"description":"A Arbrea Labs \u00e9 l\u00edder na combina\u00e7\u00e3o de tecnologia avan\u00e7ada de IA com cuidados de sa\u00fade personalizados. Nossos simuladores de Realidade Aumentada e 3D r\u00e1pidos, simples e seguros otimizam as consultas, economizando tempo e aprimorando a educa\u00e7\u00e3o do paciente. Enquanto isso, nosso impulsionador de marketing orientado por AR aprimora as jornadas dos pacientes, maximizando o ROI de marketing e promovendo a gera\u00e7\u00e3o eficiente de leads. Junte-se a n\u00f3s para moldar o futuro da sa\u00fade est\u00e9tica.","email":"info@arbrea-labs.com","legalName":"Arbrea Labs AG","foundingDate":"2018-03-04","vatID":"CHE-292.633.177","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"11","maxValue":"50"}},{"@type":"Person","@id":"https:\/\/arbrea-labs.com\/#\/schema\/person\/069e36014f41639cb4e9fb98fbdc8b21","name":"erakernaja","url":"https:\/\/arbrea-labs.com\/pt\/author\/ad39b824856cb51b\/"}]}},"_links":{"self":[{"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/posts\/56535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/users\/125"}],"replies":[{"embeddable":true,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/comments?post=56535"}],"version-history":[{"count":19,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/posts\/56535\/revisions"}],"predecessor-version":[{"id":56558,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/posts\/56535\/revisions\/56558"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/media\/55384"}],"wp:attachment":[{"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/media?parent=56535"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/categories?post=56535"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/arbrea-labs.com\/pt\/wp-json\/wp\/v2\/tags?post=56535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}